Demo

One application, start to finish.

The live demo is the real review screen, loaded with synthetic permit applications. Below is what a reviewer sees on one of them, and what happens when they decide.

The demo is invitation-only. Y Combinator partners have a login; anyone else can ask for one.

1 · The application

A site plan for an addition, on a 60 × 120 ft lot.

The applicant uploads the plan set as a PDF and gives the parcel number. GeoMunicipal looks up the parcel, which tells it the zone and which lot line faces the street, then reads every dimension on the plans.

2 · The findings, with their source

Pick a finding and the plans show where it came from.

Application case-001 · addition to a single-family residenceReviewer: staff
FailLot line W is 6.5 ft from the building; the rule requires at least 12 ft Source: 6′-6″ on sheet A-1 · rule: interior yard
ApproveEditReject
FailLot line E is 9.5 ft from the building; the rule requires at least 12 ft Source: 9′-6″ and wall height 8′-0″
PassLot line N: 36 ft, at least 12 ft required
PassLot coverage: 2,376 of 7,200 sq ft, within the limit
Staff onlyStreet setback (lot line S): left to the reviewer, never sent to the applicant without a decision
ADDITION 6'-6" 9'-6" 36'-0" 30'-0" R.O.W. (street) N

The highlighted text is the dimension as printed on the plan; its box comes from the PDF itself. The red lot line is where the parcel map puts it.

Illustration of the review screen with a synthetic application. The zoning values are a test zone (minimum 7.25 ft, or 1.5 × the wall height if more), not any city's code.

3 · The reviewer decides

Approve, edit the wording, or reject. Every choice is logged.

Fail and missing go to the applicant

Only findings a reviewer approves reach the letter. An edit changes the wording, never the facts, and is kept in the audit log with the reviewer's name.

Uncertain items stay inside the office

When the system can't decide, for example a street setback or a page it couldn't read, it marks the item for staff and never puts it in a letter on its own.

4 · The draft letter

Written from the approved findings, ready for the reviewer to sign off.

DRAFT CORRECTION LETTER — FOR STAFF REVIEW. NOT SENT. To: Sample Applicant <applicant@example.com> Re: Application case-001, addition to a single-family residence Our review of your plans found the items below. Please revise the plans and resubmit. Corrections required 1. Lot line W is 6.5 ft from the building; the rule requires at least 12 ft Reference: interior yard, lot line W 2. Lot line E is 9.5 ft from the building; the rule requires at least 12 ft Reference: interior yard, lot line E Sincerely, Plan Review Staff

The reviewer approves the letter as a whole. GeoMunicipal never sends anything itself.

In the live demo